Gallery

Waveforms, captures and bench shots from Picotronix — straight from the workbench.

Series · 7 posts

ESR sampling: how far up in frequency can the RP2350 ADC go?

The RP2350's built-in ADC samples at 500 kS/s. For repeating waveforms, Picotronix uses equivalent-time sampling: a PIO state machine measures the signal frequency precisely, and a block of samples is folded back into a single cycle (phase space), giving a much higher effective sample rate - the ESR figure shown on each screen.

This series pushes the technique from 266 kHz up to 17 MHz, where the ADC's own capture aperture finally becomes the limit. The 2.9 MHz capture is shown beside the same signal on a Tektronix TBS 2000 for comparison.

1 of 7

ESR capture Triangle wave 266KHz

The ESR modes work well for waves around the ADC sample rate. This example uses a block of 118 samples, contiguous in the time domain, and folds them back into phase space to reconstruct the waveform.

26 October 2026

2 of 7

1 MHz Square Wave from a low end generator

This wave is being reconstructed from a 95 sample set. You can see the generator bandwidth constraints on the rising and falling edges.

26 October 2026

3 of 7

2.9MHz wave captured by the Pico 2 RP2350 ADC

This is an example of an ESR technique to reconstruct a repeating waveform using a type of phase wrapping

26 October 2026

4 of 7

Actual Tektronix TBS 2000 screen shot showing the 2.9MHz wave.

This is what the Tektronix displays. Despite the RP2350 being limited to 500KS/s, it internally has a quite narrow S/H aperture and a bandwidth of about 10MHz.

26 October 2026

5 of 7

5MHz sine wave

At just under 5MHz, we can still reconstruct a sine wave from 48 samples, however in this case our buffer op-amp is beginning to show some slew rate artifacts. We replaced that with a better op amp.

26 October 2026

6 of 7

14MHz Sine Wave

At 14MHz, we can still extract a signal, but it is attenuated. The 2350 ADC has a capture aperture, and that is now a significant part of the wave period.

26 October 2026

7 of 7

The limit

At 17 MHz, we can just see a waveform. The ADC is severely attenuating the signal and acting as a LP filter. Also, to calculate the transforms from the time domain to the phase domain, we need a PIO state machine to measure the signal frequency accurately. This was where the state machine loop reached its limit.

26 October 2026

Pico with LCD Display emulator

We developed a PC based emulator for the Pico and the Pimoroni 320x240 LCD using PyRay - the Raylib library with Python 3. This involved writing a wrapper to map the PicoGraphics library onto the Raylib library. They are quite similar, so it is not a huge job. This emulator lets you write and test Pico micropython on your PC which makes screen shots easier.

26 October 2026

Workbench development setup

Using micropython on both Pico 2 module allows two instances of Thonny to run both environments. With a scope and a signal generator it is convenient to test and evaluate new sections of code.

26 October 2026

BNC Breakout Adapter

The picotronix standardizes on 3 wire 1M inputs - AC/GND/DC, so we made a Dual BNC adapter to convert those to an Industry Standard BNC that will accept x1/x10 scope probes. The switch connects the probe to either the AC input or the DC input.

26 October 2026