Series · 7 posts
ESR sampling: how far up in frequency can the RP2350 ADC go?
The RP2350's built-in ADC samples at 500 kS/s. For repeating waveforms, Picotronix uses equivalent-time sampling: a PIO state machine measures the signal frequency precisely, and a block of samples is folded back into a single cycle (phase space), giving a much higher effective sample rate - the ESR figure shown on each screen.
This series pushes the technique from 266 kHz up to 17 MHz, where the ADC's own capture aperture finally becomes the limit. The 2.9 MHz capture is shown beside the same signal on a Tektronix TBS 2000 for comparison.
1 of 7
ESR capture Triangle wave 266KHz
The ESR modes work well for waves around the ADC sample rate. This example uses a block of 118 samples, contiguous in the time domain, and folds them back into phase space to reconstruct the waveform.
26 October 2026
2 of 7
1 MHz Square Wave from a low end generator
This wave is being reconstructed from a 95 sample set. You can see the generator bandwidth constraints on the rising and falling edges.
26 October 2026
3 of 7
2.9MHz wave captured by the Pico 2 RP2350 ADC
This is an example of an ESR technique to reconstruct a repeating waveform using a type of phase wrapping
26 October 2026
4 of 7
Actual Tektronix TBS 2000 screen shot showing the 2.9MHz wave.
This is what the Tektronix displays. Despite the RP2350 being limited to 500KS/s, it internally has a quite narrow S/H aperture and a bandwidth of about 10MHz.
26 October 2026
5 of 7
5MHz sine wave
At just under 5MHz, we can still reconstruct a sine wave from 48 samples, however in this case our buffer op-amp is beginning to show some slew rate artifacts. We replaced that with a better op amp.
26 October 2026
6 of 7
14MHz Sine Wave
At 14MHz, we can still extract a signal, but it is attenuated. The 2350 ADC has a capture aperture, and that is now a significant part of the wave period.
26 October 2026
7 of 7
The limit
At 17 MHz, we can just see a waveform. The ADC is severely attenuating the signal and acting as a LP filter. Also, to calculate the transforms from the time domain to the phase domain, we need a PIO state machine to measure the signal frequency accurately. This was where the state machine loop reached its limit.